APC UPS Setup
How to set up UPS monitoring via USB, for APC UPS models.
Plug in the USB cable (dur)
Edit the UPS service in TrueNas:
2.1: Choose USB driver with closest match to APC UPS model, and choose correct USB device (usually something like /dev/ugenX.X) and set UPS name to simply ups
2.2: DO NOT check Remote Monitor
2.3: Add Monitor user and password, copy same info into the extra users section in this format (note brackets!):
[{username}]
password = {password}
actions = set
actions = fsd
instcmds = all
2.4: Set shutdown to "UPS Reaches Low Battery", set command to: shutdown -p +1 "System is shutting down due to low UPS battery!"
2.5: DO NOT set up email alerts! (otherwise you get two sets for each event due to system alerting!)
2.6: Add MAXAGE 25 to the "Auxilary Parameters (upsd.conf)" box (prevents occasional 'connection to UPS lost' errors)
Enable the service!
Check box to auto-start service.
Checking UPS status and changing parameters remotely:
upsc ups@localhost
List commands that can be run from the terminal for a particular UPS:
upscmd -u [username] -p [password] -l ups@localhost
Run a command on a UPS:
upscmd -u [username] -p [password] ups@localhost command.name.here
Typical commands:
test.start.battery.quick
test.start.battery.deep
test.start.battery.stop
beeper.disable
beeper.enable