APC UPS Setup
How to set up UPS monitoring via USB, for APC UPS models.
-
Plug in the USB cable (dur)
-
Edit the UPS service in TrueNas:
2.1: Choose USB driver with closest match to APC UPS model, and choose correct USB device (usually something like
/dev/ugenX.X
) and set UPS name to simplyups
2.2: DO NOT check
Remote Monitor
2.3: Add Monitor user and password, copy same info into the
extra users
section in this format (note brackets!):[{username}] password = {password} actions = set actions = fsd instcmds = all
2.4: Set shutdown to "UPS Reaches Low Battery", set command to:
shutdown -p +1 "System is shutting down due to low UPS battery!"
2.5: DO NOT set up email alerts! (otherwise you get two sets for each event due to system alerting!)
2.6: Add
MAXAGE 25
to the "Auxilary Parameters (upsd.conf)" box (prevents occasional 'connection to UPS lost' errors) -
Enable the service!
-
Check box to auto-start service.
Checking UPS status and changing parameters remotely:
- Check status of UPS (get all stats):
upsc ups@localhost
- List commands that can be run from the terminal for a particular UPS:
upscmd -u [username] -p [password] -l ups@localhost
- Run a command on a UPS:
upscmd -u [username] -p [password] ups@localhost command.name.here
Typical commands:
-
test.start.battery.quick
-
test.start.battery.deep
-
test.start.battery.stop
-
beeper.disable
-
beeper.enable